Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 8.000
Filtrar
1.
J Adhes Dent ; 26(1): 87-92, 2024 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-38465403

RESUMO

PURPOSE: This paper describes previously unknown details about the discovery of resin adhesion to acid-etched human enamel. MATERIALS AND METHODS: A literature review was performed through manual assessments. Primary sources revealing the discovery of resin curing on etched enamel were analyzed considering the research objectives and methodological procedure during that era, including the type of teeth used, preparatory measures, acid-etching process, type of resin and its application, and follow-up observations. Additionally, the political and economic contexts were examined. RESULTS: In 1949, acid etching was found to promote adhesion with acrylic resin, a finding described again in 1955. The 1949 studies utilized nitric acid for enamel etching and the acrylate resin Paladon from the Kulzer company (Germany). Conversely, the 1955 investigations employed phosphoric acid and an unnamed acrylate, likely a self-curing resin supported by Kulzer in the late 1930s. Disparities in the 1949 and 1955 findings can be ascribed to varying objectives and test conditions amidst a turbulent political backdrop, significantly impacting the Kulzer company. CONCLUSION: The discovery of resin adhesion to acid-etched enamel, approaching its 75th anniversary in 2024, is a landmark in 20th-century adhesive dentistry. Paladon represents a pioneering compound, exemplifying the influence of political, ideological, and economic factors on scientific advancements during that period.


Assuntos
Colagem Dentária , Humanos , Condicionamento Ácido do Dente/métodos , Microscopia Eletrônica de Varredura , Propriedades de Superfície , Esmalte Dentário , Ácidos Fosfóricos , Acrilatos , Cimentos de Resina , Teste de Materiais
2.
J Long Term Eff Med Implants ; 34(3): 1-7, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38505886

RESUMO

Inflammation that occur as a part of body's response to implant-tissue contact can result in oxidative stress. Therefore, exploring the oxidative stress around different surface treated dental implants is essential to improve the performance of implants. The purpose of this study was to detect and measure the level of malondialdehyde (MDA), oxidative stress marker among patients with sandblasted acid-etched and anodized surface dental implants. In this prospective clinical study, 78 patients who had undergone implant placement for missing single posterior tooth in mandible using sandblasted acid-etched and anodized surface dental implants during August 2019 - December 2019 were enrolled according to strict inclusion and exclusion criteria and were categorized into Group 1: SLA (n = 27), Group 2: SLActive (n = 26), Group 3: TiUnite (n = 25) based on the surface modification of the implants. Peri-implant crevicular fluid (PICF) was collected and MDA was quantified using ELISA kit at 3 months and 1 year. Statistical analysis was performed using one-way ANOVA, followed by Tukey's HSD post hoc. For intragroup comparison, paired t-test was used. MDA levels in group 3 implants was significantly higher than groups 1 and 2 (P ≤ 0.05). On pairwise comparison, there was a statistically significant difference between the groups at baseline (P ≤ 0.05) and 1-year follow-up (P ≤ 0.05). Intragroup comparison showed that there was a statistically significant difference from baseline in all the three groups (P ≤ 0.05). MDA level in peri-implant crevicular fluid was high around TiUnite dental implant as compared to SLA and SLActive implants.


Assuntos
Implantes Dentários , Humanos , Estudos Prospectivos , Condicionamento Ácido do Dente , Propriedades de Superfície , Osseointegração/fisiologia , Titânio , Planejamento de Prótese Dentária , Implantação Dentária Endóssea
3.
Braz Dent J ; 35: e245641, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38537017

RESUMO

This study verified the effect of the combination of preheated hydrofluoric acid/silane/electric current in the adhesion of the resin cement to ceramic. IPS E.max Press ceramic discs embedded in PVC rigid tubes were divided into four groups associating preheated hydrofluoric acid and silane applied with electrical current (n=10): Ha+S (Heated acid + silane); Ha+S+Ec (Heated acid + silane + electrical current); A+S (Acid + silane) and A+S+Ec (Acid + silano + electrical current). Resin cement/ceramic samples were stored in water at 37°C for 24h. After storage, they were submitted to the microshear test, fracture analysis, and contact angle at 24h or after thermocycling (10,000 cycles/5-55ºC). Bond strength data were evaluated by two-way ANOVA. For comparison between evaluation times (24h or thermocycling) was applied unpaired t-test. A significance post-hoc test of p=0.05 was assumed for analyses and graphs (GraphPad Prism 9.0 software). At 24h, the microshear strength showed similar values between Ha+S, Ha+S+Ec, and A+S+Ec groups, while A+S showed the lowest value with a statistical difference. After thermocycling, Ha+S and Ha+S+Ec were similar, as well as A+S and A+S+Ec. There was a significant difference in all groups comparing 24h (highest value) with after thermocycling (lowest value). Adhesive fracture was predominant in all groups and evaluation times. Ha+S and A+S groups showed higher contact angle values compared to the Ha+S+Ec and A+S+Ec with lower values. In conclusion, the association of preheated hydrofluoric acid/silane applied or not with electric current promoted different microshear strength values, fracture types, and contact angles in the resin cement/ceramic bond.


Assuntos
Colagem Dentária , Cimentos de Resina , Cimentos de Resina/química , Silanos/química , Ácido Fluorídrico/química , Propriedades de Superfície , Condicionamento Ácido do Dente , Cerâmica/química , Porcelana Dentária/química , Teste de Materiais
4.
BMC Oral Health ; 24(1): 171, 2024 Feb 02.
Artigo em Inglês | MEDLINE | ID: mdl-38308281

RESUMO

BACKGROUND: To assess the micro tensile bond strength (µTBS) of two resin matrix ceramic (RMC) blocks bonded to composite resin by using different repair protocols with and without chewing simulation (CS). MATERIALS AND METHODS: Two resin matrix ceramic blocks (Vita Enamic and Lava Ultimate) were divided into 4 groups according to the surface treatments: Bur grinding (control), Bur grinding + silane, 9.5% HF acid etching, and 9.5% HF acid etching + silane. The single bond universal adhesive was applied on all specimens after the surface treatments according to the manufacturer's instructions, it was administered actively on the treated surface for 20 s and then light cured for 10 s, followed by incremental packing of composite resin to the treated surface. Each group was further divided into 2 subgroups (with/without chewing simulation for 500,000 cycles). A micro tensile bond strength test was performed for each group (n = 15). The effect of surface treatments on the materials was examined by using a scanning electron microscope (SEM). The micro tensile bond strength (MPa) data were analyzed with a three-way ANOVA, the independent t-test, and one-way ANOVA followed by the Tukey post-hoc test. RESULTS: µTBS results were significantly higher for Lava Ultimate than Vita Enamic for all the surface treatment protocols with (p < 0.01). The chewing simulation significantly negatively affected the micro-tensile bond strength (p < 0.001). Bur grinding + saline exhibited the highest bond strength values for Lava Ultimate, both with and without chewing simulation. For Vita Enamic, bur grinding + saline and HF acid + saline showed significantly higher bond strength values compared to other surface treatments, both with and without chewing simulation (p ≤ 0.05). CONCLUSION: Bur grinding + silane could be recommended as a durable repair protocol for indirect resin matrix ceramics blocks with composite resin material.


Assuntos
Resinas Compostas , Colagem Dentária , Humanos , Resinas Compostas/química , Porcelana Dentária/química , Silanos/química , Mastigação , Condicionamento Ácido do Dente/métodos , Propriedades de Superfície , Cimentos de Resina/química , Cerâmica/química , Teste de Materiais , Resistência à Tração , Análise do Estresse Dentário
5.
Dent Mater J ; 43(2): 200-206, 2024 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-38296510

RESUMO

To investigate the mechanism underlying high acid resistance of enamel after erbium laser etching. Forty-five premolars were collected and assigned to three groups. A 4×4×1 mm enamel sample was prepared, the left side was the control side, the right side was the treated side, which was treated with different surface treatments, including 35% phosphoric acid etching, Er:YAG laser etching, and Er,Cr:YSGG laser etching. The hydroxyapatite crystal size on the enamel surface of the samples was observed. The contents of Ca, P, O, F, Cl, C, Mg were detected. The crystallinity of the hydroxyapatite crystal was analyzed. After erbium laser etching, the enamel surface had high hydroxyapatite crystal size, beneficial content of chemical elements and crystallinity. The morphological and composition changes of crystals in the enamel surface after erbium laser etching may be one of the crucial mechanisms underlying the enhancement of acid resistance of enamel after erbium laser etching.


Assuntos
Colagem Dentária , Lasers de Estado Sólido , Érbio/farmacologia , Condicionamento Ácido do Dente , Esmalte Dentário , Hidroxiapatitas/farmacologia
6.
Caries Res ; 58(1): 17-29, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37797597

RESUMO

Red-fluorescing dentine indicates bacterial contamination [Caries Res 2002; 36: 315-319]. We investigated effect of removal of red fluorescent dentine caries on shear bond strength and fracture mode of 4 adhesive approaches. Sixty-five carious teeth and 50 noncarious controls were distributed into 4 groups: Clearfil™ self-etch (CSE), OptiBond™ FL total etch (OTE), Scotchbond™ Universal total etch (STE) and self-etch (SSE). Samples were excited at 405 nm and viewed through 530 nm filter. Carious samples were ground flat exposing strongly red-fluorescing (StrongRF) dentine, on which a composite cylinder was placed, using one of 4 adhesives. After 22 h in water, shear bond strength and fracture mode were analysed. StrongRF was removed; composite cylinders were placed on weakly red-fluorescing (WeakRF) dentine and tested as described above. Finally, red-fluorescing dentine was removed, and composite cylinders were placed on non-fluorescing (NonRF) dentine and tested. Composites were placed at 3 corresponding heights in controls. After 22 h in water, shear bond strength testing and fracture mode analysis were performed. Differences were tested using Mann-Whitney or Wilcoxon tests (p ≤0.05). Median (Q1, Q3) shear bond strength on StrongRF was SSE 14.4 (9.2, 18.2) MPa >CSE 10.2 (6.4, 17.3) MPa >STE 9.1 (6.9, 11.2) MPa >OTE 6.8 (4.0, 10.8) MPa. Shear bond strength increased statistically significantly for all adhesives on WeakRF: SSE 19.8 (13.6, 24.3) MPa >STE 19.5 (12.7, 23.1) MPa >CSE 17.5 (12.0, 22.5) MPa >OTE 15.8 (11.9, 20.9) MPa. Only STE 25.6 (22.4, 29.1) MPa and CSE 22.1 (17.6, 24.6) MPa were significantly different on NonRF compared to WeakRF. For controls tested at corresponding depths, superficial shear bond strength was OTE 18.7 (16.0, 22.1) MPa >STE 18.4 (12.0, 25.9) MPa >CSE 18.1 (12.7, 20.7) MPa >SSE 13.0 (9.6, 17.8) MPa. This was significantly higher compared to StrongRF except for SSE. Central shear bond strength was not significantly different to WeakRF, deep shear bond strength was significantly lower for SSE and CSE but higher for OTE compared to carious. Conclusion: StrongRF dentine should be removed for higher shear bond strength, but WeakRF dentine can often be preserved without compromising adhesive bond strength.


Assuntos
Resinas Compostas , Colagem Dentária , Humanos , Resinas Compostas/química , Cimentos Dentários , Adesivos Dentinários/química , Cimentos de Resina/química , Condicionamento Ácido do Dente , Dentina , Água , Teste de Materiais
7.
Dent Mater ; 40(1): 44-52, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37891131

RESUMO

OBJECTIVES: To examine whether dentin-etching extension and/or the hydrophobic-rich content of hybrid layers would affect fatigue strengths of a mild universal adhesive after long-term aging. METHODS: Twin-bonded resin-dentin interfaces were produced by etching sound midcoronal dentin beams with 32 % ortho-phosphoric acid for 15 s (OPA15s), 3 s (OPA3s) or 10 % meta-phosphoric acid for 15 s (MPA15s). Samples were bonded with a mild universal adhesive with or without additional coating using a solvent-free bisGMA-based bonding resin. Self-etch application served as control. Composite buildups were made with a nanofilled composite. Bar-shaped twin-bonded interfaces (0.9 × 0.9 × 12 mm) were aged for two years in artificial saliva at 37 â„ƒ and tested under 4-point flexure at quasi-static (n = 16) and cyclic loads (n = 35) until failure. The stress-life fatigue behavior was evaluated using the staircase method at 4 Hz. Crack initiation and fracture patterns were evaluated by SEM. Cyclic-loaded data was analyzed by Kruskal-Wallis on Ranks (α = 0.05). RESULTS: Significantly higher fatigue life distributions and higher endurance limits were observed for less aggressive etch-and-rinse protocols (OPA3s and MPA15s) after long-term ageing. Hydrophobic-rich coating produced 20-32 % higher endurance limits, prevented micrometer-sized porosities at bonded interfaces, reduced etching-associated variability and lowered crack formation. Significance Long-term hydrolysis produces detrimental effects on the fatigue strength of resin-dentin interfaces. The bond-promotion effect of less aggressive etch-and-rinse protocols and the creation of hybrid layers with higher hydrophobic-rich content are critical to extend the durability of mild universal adhesives. Therefore, current oversimplification trends in adhesive dentistry may limit resin-dentin bonding performance.


Assuntos
Colagem Dentária , Cimentos Dentários , Adesivos Dentinários , Cimentos de Resina , Condicionamento Ácido do Dente/métodos , Colagem Dentária/métodos , Dentina , Teste de Materiais , Resistência à Tração , Adesivos
8.
Oper Dent ; 49(1): 52-64, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38019213

RESUMO

The present study aimed to evaluate the influence of application mode on the short-term microshear bond strength longevity of self-etching and universal adhesive systems to enamel, the failure mode, and the resulting enamel surface micromorphology. Ninety enamel surfaces were obtained from sound third molars, planed, and randomly assigned to nine groups, according to the application mode and the adhesive system (n=10). There were three primer application modes: according to the manufacturer's recommended application time (control), using double the application time recommended for the primer and selective enamel etching. The adhesive systems used were: Clearfil SE Bond (Kuraray), FL-Bond II (SHOFU), and Futurabond U (Voco). At least two resin-bonded composite cylinders (Grandioso Light Flow, Voco) were placed on each enamel surface, and then evaluated for microshear bond strength at 24 hours and 180 days of storage in solution body fluid (SBF) at pH 7.4. Failure modes were evaluated with a stereoscopic microscope at 20× magnification. A micromorphological analysis of the enamel surface was performed under a scanning electron microscope at 5000× magnification before and after the treatments. Mixed models for repeated measures over time showed significant interaction among application modes, adhesive systems, and time periods (p=0.0331). The bond strength of FL-Bond II adhesive to enamel observed after performing selective enamel etching was significantly higher than that observed after applying the control treatment (p=0.0010) at both 24 hours and 180 days. However, no significant difference was observed between the application of this same adhesive at double the time recommended by the manufacturer and the other two application modes (p>0.05). There was also no significant difference in the microshear bond strength for the enamel treatments applied using Clearfil SE Bond and Futurabond U (p>0.05). A significant reduction in bond strength to enamel was observed at the 180-day storage time for all the adhesive systems when selective enamel etching was performed (p<0.0001). No significant association was observed between the adhesive system failure mode and the enamel treatments (p=0.1402 and p=0.7590 for 24 hours and 180 days, respectively). The most prevalent failure was the adhesive type.


Assuntos
Colagem Dentária , Cimentos Dentários , Cimentos Dentários/química , Colagem Dentária/métodos , Condicionamento Ácido do Dente/métodos , Resinas Compostas/química , Cimentos de Resina/uso terapêutico , Cimentos de Resina/química , Esmalte Dentário , Teste de Materiais , Resistência ao Cisalhamento , Adesivos Dentinários/química
9.
Dent Mater J ; 43(1): 58-66, 2024 Jan 30.
Artigo em Inglês | MEDLINE | ID: mdl-38008438

RESUMO

Dental bases require low thermal conductivity and good mechanical properties, such as bonding with composite resins. This study aims to elucidate the physicochemical properties of premixed mineral trioxide aggregate (MTA) for its suitability as a dental base and to explore the optimal adhesive strategy with composite resin. The thermal conductivity and compressive strength of this premixed MTA are 0.12 W/(m•K) and 93.76 MPa, respectively, Which are deemed adequate for its application as dental base. When bonded to composite resin, the use of 37% phosphoric acid etching before applying the Clearfil SE bond significantly reduced the bonding strength between composite resin and premixed MTA. This was because the compressive strength and Vickers hardness of premixed MTA decreased, and tricalcium silicate was dissolved from the surface during acid etching. Therefore, it is recommended to avoid using 37% phosphoric acid etching when bonding premixed MTA and composite resin as a dental base.


Assuntos
Compostos de Alumínio , Compostos de Cálcio , Resinas Compostas , Colagem Dentária , Óxidos , Ácidos Fosfóricos , Silicatos , Resinas Compostas/química , Cimentos de Resina/química , Condicionamento Ácido do Dente , Propriedades de Superfície , Teste de Materiais , Resistência ao Cisalhamento , Combinação de Medicamentos
10.
Artigo em Inglês | MEDLINE | ID: mdl-37819852

RESUMO

Ultrathin ceramic veneers are a viable therapeutic option to manage esthetic challenges in the anterior zone. Proper conditioning of the intaglio surface of porcelain veneers is essential to achieve an adequate bonding. In clinical practice, this is typically done with chemical etching using an acid-containing agent, such as hydrofluoric acid. While it is well established that the etching effect is dependent on etching time and the acid concentration, little is known about the impact of etching time and the veneer fabrication method. The purpose of this pilot study was to evaluate, using scanning electron microscopy (SEM), the effect that different etching-time protocols have on the intaglio surface characteristics of ultrathin ceramic veneers fabricated with either the platinum foil technique or the refractory die technique. Several replicas of an ultrathin feldspathic ceramic veneer for a maxillary central incisor were fabricated. Individual specimens were processed according to different intaglio surface-etching protocols: no etching, etching for 90 seconds, etching for 120 seconds, and etching for 150 seconds (9.6% hydrofluoric acid used for all etching groups). It was observed that the 120-second etching protocol resulted in a favorable microroughness surface pattern in the platinum foil group. This pattern was comparable to that obtained by etching for 90 seconds with hydrofluoric acid the intaglio surface of veneers fabricated with the refractory die technique. Increasing the etching time to 150 seconds did not result in a more favorable roughness pattern.


Assuntos
Colagem Dentária , Porcelana Dentária , Humanos , Ácido Fluorídrico , Microscopia Eletrônica de Varredura , Platina , Projetos Piloto , Condicionamento Ácido do Dente/métodos , Propriedades de Superfície , Cerâmica , Teste de Materiais , Cimentos de Resina
11.
J Mech Behav Biomed Mater ; 150: 106338, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38159495

RESUMO

The aim of this study was to mechanically characterize through flexural fatigue test two CAD-CAM glass-ceramics according to distinct surface etching protocols. To do so, feldspathic (FELD) and lithium disilicate (LD) glass ceramics were subjected to different surface treatments: (1) control - no treatment (Ctrl); (2) conventional protocol etching with 5% hydrofluoric acid followed by silane coupling agent application (HF + SIL; Monobond N, Ivoclar); or (3) using a self-etching ceramic primer (E&P; Monobond Etch & Prime, Ivoclar). Ceramic discs (N = 120; Ø = 12 mm; thickness = 1.2 mm) were produced from CAD-CAM blocks, with 60 being from FELD (VITABLOCS Mark II, Vita Zahnfabrik) and 60 from LD (IPS e.max CAD, Ivoclar). Next, 20 disks of each ceramic were allocated into three groups: Ctrl, HF + SIL, or E&P. Surface roughness data were collected on all samples before and after surface treatments (except for Ctrl). Cyclic fatigue (n = 15) biaxial flexural strength tests were performed by the piston-on-three-balls geometry (ISO 6872) considering the test parameters established from a monotonic test (n = 5). The monotonic test was carried out at a 1 mm/min loading rate and 500 kgf loading cell until fracture to obtain the failure data. The cyclic fatigue test was executed underwater at a frequency up to 20 Hz, with the first stress being 25% of the monotonic test for 5000 cycles, followed by increments of 5% of the monotonic test at each step of 10,000 cycles until failure (fracture). Complementary fractography, topography and Atomic Force Microscopy (AFM) analyses were performed. Characteristic Fatigue Strength (CFS) and Weibull modulus were analyzed by Weibull analysis using the fatigue test data. Roughness and complementary analysis data were analyzed by one-way ANOVA. The statistical results exhibited similar CFS among Ctrl, HF + SIL and E&P for both glass-ceramics. The survival analysis corroborates the findings, however the Weibull modulus pointed out superior structural reliability of FELD treated with the E&P group compared to HF + SIL. According to the complementary analyses, HF + SIL exhibited a higher surface area than E&P and Ctrl for FELD (p = 0.001). Roughness showed statistically significant differences among conditions for FELD (E&P < Ctrl = HF + SIL; p < 0.05) and no difference for LD (p > 0.05). Therefore, the CFS were not influenced by any condition evaluated for FELD and LD glass-ceramics; however, superior structural reliability (higher Weibull modulus) for the feldspathic ceramic treated with the E&P was observed.


Assuntos
Colagem Dentária , Silanos , Propriedades de Superfície , Silanos/química , Ácido Fluorídrico , Reprodutibilidade dos Testes , Teste de Materiais , Condicionamento Ácido do Dente , Cerâmica/química , Porcelana Dentária , Análise do Estresse Dentário , Cimentos de Resina
12.
J Adhes Dent ; 25(1): 231-240, 2023 Nov 02.
Artigo em Inglês | MEDLINE | ID: mdl-37975312

RESUMO

PURPOSE: To conduct a systematic review and meta-analysis of in-vitro bond strength to glass-ceramics using hydrofluoric acid (HF) at lower (<5%) and higher (>5%) concentrations ([HF]) to treat ceramic surfaces. METHODS: Systematic searches were carried out in PubMed, Scopus, LILACS, and Web of Science for articles published through July 2021, and a meta-analysis was performed to estimate the combined effect by comparing the differences between the standardized means of the bond strengths of the evaluated materials. RESULTS: In total, 943 articles were found, of which 17 studies were selected for qualitative analysis and 12 for quantitative analysis. The bond strength to glass-ceramics using 4% to 5% HF did not differ from that using 7% to 10% HF for the following HF etching times and glass-ceramic materials: 20 s for lithium-disilicate (Z = 0.65, p = 0.51), 60 s for feldspathic (Z = 0.53, p = 0.60), and 60 s for leucite (Z = 0.72, p = 0.35). CONCLUSION: The lower concentration HF (<5%) etchant is a reliable surface treatment for adhesive bonding to glass-ceramics with satisfactory bond strength in short-term evaluations.


Assuntos
Colagem Dentária , Ácido Fluorídrico , Ácido Fluorídrico/química , Condicionamento Ácido do Dente , Cimentos de Resina/química , Propriedades de Superfície , Teste de Materiais , Cerâmica/química , Porcelana Dentária/química
13.
J Dent Res ; 102(13): 1444-1451, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37950512

RESUMO

Dental caries is the most common oral disease and the most common cause of resin restorations. In minimally invasive dentistry, the principle behind cavity preparation is to remove external caries-infected dentin (CID) and preserve internal caries-affected dentin (CAD) and sound dentin (SD). The cavity floor is mainly composed of CAD, but the poor bonding performance of CAD has become a widespread concern. This study evaluated the performance of a new collagen-reactive monomer (ITCM) used as a primer to improve the bonding performance of CAD. The experimental specimens were grouped as follows: SD, CAD, and ITCM-pretreated CAD (CAD-ITCM). Dentin slices were obtained for attenuated total reflectance-Fourier transform infrared (ATR-FTIR) analysis. The bonded samples were subjected to microtensile bond strength analysis after 24 h of water storage or aging by thermocycling, and the bonding interface quality was evaluated by nanoleakage assessment, interfacial nanoindentation testing, and in situ zymography. Cytotoxicity experiments with ITCM were performed. ATR-FTIR showed that the isocyanate groups in ITCM can covalently bind and form hydrogen bonds with the collagen in CAD to mediate chemical bonding. ITCM pretreatment significantly improved the bond strength of CAD (P < 0.05), reduced interfacial nanoleakage, improved the sealing of the bonding interface, enhanced the homogeneity of the hybrid layer, and inhibited matrix metalloproteinase activity. In addition, ITCM presented acceptable biocompatibility for dental restorative application. Taken together, this study reported the application of ITCM to induce collagen-based chemical bonding in the CAD bonding system, which fills the gap in strategies to improve the bonding performance of CAD immediately and after aging and has important clinical application prospects.


Assuntos
Colagem Dentária , Cárie Dentária , Humanos , Resinas Compostas/química , Adesivos Dentinários/química , Suscetibilidade à Cárie Dentária , Cimentos de Resina/química , Dentina , Resistência à Tração , Condicionamento Ácido do Dente , Teste de Materiais , Colágeno
14.
J Indian Soc Pedod Prev Dent ; 41(3): 258-264, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37861642

RESUMO

Introduction: The cornerstone of preventative therapy is made up of pit and fissure sealants and fluorides. Resin sealants have been shown to help reduce fissure decay in both primary and permanent teeth. Etching of primary molars is not effective due to prismless enamel, higher organic content, and diversity in fissure shape. Methods of pretreatment of pits and fissures have been hypothesized to promote microporosities in etched enamel and hence sealant adherence. Examining the etching pattern and surface roughness of the enamel surface can be used to gauge these. Objective: This study aimed to evaluate the effect of pretreatment with ozone gas and 5.25% sodium hypochlorite solution on pits and fissures of primary teeth to check for the etching pattern and surface roughness. Materials and Methods: Thirty noncarious primary molars were sectioned to retain the crowns, and randomly divided into three groups, sodium hypochlorite, ozone gas, and control. Each sample was pretreated with the agent, washed, followed by etching with 37% phosphoric acid. Samples were sectioned and subjected to scanning electron microscope analysis to evaluate the etching pattern and surface roughness. Results: Comparison of the etching pattern in three groups showed a statistically insignificant difference (P=0.364). Surface roughness was highest in the hypochlorite group followed by ozone and control which showed a statistically significant difference (P = 0.001). The surface area between the three groups showed a statistically insignificant difference. Conclusion: Sodium hypochlorite is a better pretreatment agent compared to ozone gas and acid etching alone. However, as all results were not statistically significant further research must be carried out to prove the effectiveness of these agents.


Assuntos
Colagem Dentária , Hipoclorito de Sódio , Humanos , Hipoclorito de Sódio/farmacologia , Microscopia Eletrônica de Varredura , Condicionamento Ácido do Dente/métodos , Selantes de Fossas e Fissuras , Dente Decíduo , Ácidos Fosfóricos
15.
Dent Mater ; 39(11): 1051-1057, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37793951

RESUMO

OBJECTIVE: To evaluate the effect of dimethyl sulfoxide (DMSO) on the microtensile bond strength (µTBS) and nanoleakage (NL) of universal adhesives on eroded dentine, immediately and after four years of water storage. METHODS: Sixty-four sound human molars were distributed into 16 groups according to (1) Dentine surface (sound and eroded dentine); (2) dimethyl sulfoxide application (with or without); (3) Application mode (etch-and-rinse or self-etch) and (4) Storage time (immediate and four years). One mild universal adhesive was used (Scotchbond Universal). The restoration was then performed with a composite resin and the specimens were sectioned into resin-dentine bonded sticks. Resin-dentine bonded sticks were tested (immediately and after four years of water storage) for µTBS (0.5 mm/min) or used to assess NL. Data on µTBS and NL were analyzed using four-way ANOVA and Tukey's test (α = 0.05). RESULTS: Only the 3-way cross-product interaction 'substrate vs DMSO vs time' was statistically significant (p = 0.007). Eroded dentine showed a lower mean of µTBS and a higher mean of NL values than sound dentine. However, when DMSO was applied, no significant decrease of µTBS or NL values was observed after four years of water storage, regardless of adhesive strategies, or dentine evaluated, when compared to immediate results. SIGNIFICANCE: Water-based DMSO pre-treatments not only prevent degradation of MDP-containing simplified adhesives but also serve as a potential alternative to improve long-term bonding properties to eroded dentine. The versatility of using a single pre-treatment for both self-etch or etch-and-rinse bonding to eroded dentin may facilitate future clinical applications.


Assuntos
Colagem Dentária , Dimetil Sulfóxido , Humanos , Cimentos Dentários , Colagem Dentária/métodos , Adesivos Dentinários/química , Condicionamento Ácido do Dente/métodos , Cimentos de Resina/química , Dentina , Água/química , Resistência à Tração , Teste de Materiais
16.
J Adhes Dent ; 25(1): 177-186, 2023 Aug 08.
Artigo em Inglês | MEDLINE | ID: mdl-37800873

RESUMO

PURPOSE: This follow-up of a randomized clinical split-mouth study aimed to investigate the influence of selective enamel etching on the long-term clinical performance of partial ceramic crowns (PCCs) luted with a self-adhesive resin cement. MATERIALS AND METHODS: 43 patients received two PCCs (Vita Mark II; Cerec 3D) each for the restoration of extensive lesions with multiple cusp coverage, inserted with a self-adhesive resin cement (RelyX Unicem, RXU). Using a split-mouth design, one PCC received additional selective enamel etching (RXU+E) and one did not (RXU-E). Patients were clinically evaluated at baseline and after up to 15 years (median observation period 176 months) using modified USPHS and FDI criteria. The data were analyzed non-parametrically (chi-squared tests, α = 0.05). Clinical survival of all restorations after 15 years was evaluated using the Kaplan-Meier analysis. RESULTS: After 15 years, 19 patients were available for clinical assessment (recall rate: 56%). Kaplan-Meier analysis showed a cumulative survival of 78.1% for RXU+E and of 42.9% for RXU-E, indicating a significantly higher survival rate for RXU+E (p = 0.004). Regarding the clinical performance of PCCs available for the 15-year evaluation, no statistically significant differences were found between RXU+E and RXU-E using modified USPHS and FDI criteria. Both groups revealed significant deterioration over time regarding surface luster, marginal adaptation, and marginal discoloration. RXU+E resulted in significantly inferior anatomic form over time and a significant improvement in post-operative hypersensitivity compared to baseline. CONCLUSION: For posterior PCCs, selective enamel etching can be recommended based on higher survival rates after 15 years. Clinically, deterioration due to aging is similar in both groups.


Assuntos
Coroas , Cimentos de Resina , Humanos , Cimentos Dentários , Condicionamento Ácido do Dente/métodos , Cerâmica , Esmalte Dentário
17.
J Adhes Dent ; 25(1): 159-166, 2023 Aug 08.
Artigo em Inglês | MEDLINE | ID: mdl-37551926

RESUMO

PURPOSE: To evaluate the bond strength between alternative or conventional luting agents and indirect restorative materials. MATERIALS AND METHODS: Blocks of a polymer-infiltrated ceramic network (PICN, Vita Enamic) and a feldspathic ceramic (FEL, Vita Mark II) were sliced and divided according to the luting agent: resin cement (PICN-RC, FEL-RC), flowable composite (PICN-FC, FEL-FC), or preheated composite (PICN-PH, FEL-PH). The ceramic surfaces were polished, etched with 5% hydrofluoric acid for 60 s, and then a silane layer was applied. Cylinders of the luting agents were built up on the ceramic surfaces. In half the samples, the microshear bond strength (µSBS) was tested after 24 h (baseline). The other half was tested after 5000 thermocycles (5°C-55°C) (aging). The failure modes were determined using a stereomicroscope, and the ceramic surfaces were analyzed using a scanning electron microscope. Data were statistically analyzed with two-way ANOVA. RESULTS: Thermocycling reduced the bond strength values of all experimental groups. Regarding FEL, the preheated composite obtained the highest results. Resin cement showed results similar to the flowable composite at baseline and after aging. The highest results of PICN were obtained from the preheated composite followed by resin cement and flowable composite. Significant differences among the three luting agents were observed before and after aging. The most frequent failures among the experimental groups were adhesive and cohesive in the ceramic. CONCLUSION: Bond strength results indicate that the preheated composite can be an alternative for adhesive cementation when applied on the tested feldspathic ceramic or PICN.


Assuntos
Colagem Dentária , Cimentos de Resina , Cimentos de Resina/química , Propriedades de Superfície , Condicionamento Ácido do Dente/métodos , Cerâmica/química , Porcelana Dentária/química , Cimentos Dentários , Silanos/química , Teste de Materiais , Ácido Fluorídrico/química
18.
Dent Mater J ; 42(4): 581-590, 2023 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-37302822

RESUMO

This study aimed to evaluate the effect of different matrix metalloproteinase inhibitors (MMPIs) on the microtensile bond strength (µTBS) and nanoleakage of universal adhesives. One hundred twenty non-carious human molars were prepared and randomly assigned to two groups: Scotchbond Bond Universal (SBU) and Gluma Bond Universal (GBU). The samples in each group were assigned to five subgroups (n=12) based on one control (water) and four MMPIs (Benzalkonium-chloride (BAC), Batimastat (BB94), Chlorhexidine (CHX), and Epigallocatechin-gallate (EGCG)). Each adhesive was applied in self-etch (SE) mode or etch-and-rinse (ER) mode. Dentin/composite sticks were fabricated and subjected to the µTBS test after 24 h or 6 months. At 6 months, MMPIs did not affect the µTBS of the adhesives, regardless of etching mode. Nanoleakage was more pronounced in ER mode than in SE mode for all subgroups. All MMPIs, with the exception of CHX, decreased the nanoleakage of GBU in ER mode.


Assuntos
Colagem Dentária , Cimentos Dentários , Humanos , Condicionamento Ácido do Dente , Adesivos , Dentina , Adesivos Dentinários/química , Teste de Materiais , Inibidores de Metaloproteinases de Matriz , Cimentos de Resina/química , Resistência à Tração , Dente Molar
19.
Dent Mater J ; 42(4): 552-558, 2023 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-37271540

RESUMO

To investigate the influence of phosphoric acid etching on the dentin enamel junction (DEJ) using optical coherence tomography (OCT). Human teeth were assigned to four groups: 1. control, no additional treatment (CT); 2. The primer of "SE Bond2" was applied (SE), 3. "Enamel Conditioner" was applied (EC), 4. "K-etchant syringe" was applied (KE). After treatment, the DEJ was observed using a laser microscope (CLSM), OCT, and scanning electron microscopy (SEM). Additionally, an ultimate tensile strength (UTS) test at the DEJ was performed. No cracks were observed by CLSM. In contrast, cracks were observed all samples by SEM. Additionally, OCT revealed a white line along the DEJ in all KE specimens and some EC specimens. The UTS test showed a significant difference between CT and KE. This study found that phosphoric acid etching may cause excessive demineralization and weaken the DEJ. This fragility was observed using a non-invasive diagnostic method using OCT.


Assuntos
Colagem Dentária , Cimentos de Resina , Humanos , Tomografia de Coerência Óptica/métodos , Condicionamento Ácido do Dente/métodos , Ácidos Fosfóricos , Esmalte Dentário , Dentina , Microscopia Eletrônica de Varredura , Colagem Dentária/métodos
20.
Mymensingh Med J ; 32(2): 550-555, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37002770

RESUMO

The present invitro type of study has done to check the effect of blood contamination & chlorhexidine combination on the bond strength of brackets bonded with self-etch primer technique. The study consisted of ninety sound human upper premolars (extracted for orthodontic purpose) fixed in a self-cure acrylic block and segregated into three groups of 30 samples each. 0.022 slot metal MBT brackets (Gemini series-3M unitek) were bonded with self-etch primer using Transbond XT composite, CA, USA and light cure for 40 seconds) on clean buccal surface. Teeth were divided into 3 groups-Group A/Control group, Group B, Group C. A computer was used to record the force applied to debond the bonded bracket in the unit of Newton. The analysis of variance indicated that there were significant differences (F value = 6.891, p value=0.002) in bond strengths between the various groups tested. The highest value of shear bond strength occurred when chlorhexidine (Group C) was used to remove the blood contamination (mean=15.874 MPa). When bonding was done in ideal condition (Group A), shear bond strength obtained was slightly lower (mean=14.497 MPa) as compared to Group C. On the other hand, lowest shear bond strength among all three groups occurred when blood contamination (Group B) was removed with water (mean=11.059 MPa). Analysis of the study showed that shear bond strength of orthodontic brackets to enamel significantly decreased during bonding with self-etch primer in blood contamination condition. Self-etch primer displayed considerably superior performance with the use of chlorhexidine instead of water to wash the blood contamination.


Assuntos
Clorexidina , Braquetes Ortodônticos , Humanos , Clorexidina/farmacologia , Condicionamento Ácido do Dente/métodos , Teste de Materiais , Resistência ao Cisalhamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...